One platform. Five modules. Every interval.

Measure, predict, dispatch, verify and bill on one data model, from the meter on your incomer to the report on the boardroom table.

Regens Smart Energy Management

The measurement layer. Every result Regens reports is verified against this data, so it has to be complete and honest about its own gaps.

  • Interval data from smart meters on incomers, feeders and major loads
  • Meter coverage per site, with Live, Delayed and No data states on every reading
  • Power factor, kVA and consumption roll-ups from meter to site to portfolio
  • A meter that stops reporting shows a dash, never 0 kW
Meter coverage · Plant A
Reporting46/ 48meters
Delayed1> 2× interval
No data1last 13:02
MeterLoadStateDemand (kW)
MTR-0101Incomer ALive1,205
MTR-0102Incomer BLive438
MTR-0142Chiller plantDelayed613
MTR-0167Lighting DB-3No data—
Meter MTR-0142 stopped reporting at 14:32. Check the gateway connection.

Regens Smart Demand Management

RSDM forecasts each site's unmanaged maximum demand and sets the target for the guaranteed shave: forecast MD less the guaranteed kW. It then sizes the shave for every 30-minute interval, and everything else on the platform works to that number.

  • Real-time demand per incomer, on the 30-minute interval and 14:00–22:00 working-day peak period TNB bills on
  • Interval forecasts of what the site would draw without Regens
  • Targets per site, re-set as the forecast moves so the guaranteed kW holds
  • Dispatch requests handed to RSSO, which decides the source mix
Site demand vs target · Thu 17 Sep
Unmanaged peak2,318kW14:30
Guaranteed shave600kWper SLA
Billed MD1,718kW600 kW shaved
UnmanagedWith RegensShavedTarget

Regens Smart Source Optimization

Hybrid source dispatch. The RSSO decides which source carries the load and when battery storage discharges, and keeps state of charge in range for the next peak.

  • Battery storage dispatch sized to each interval, not a fixed block
  • Source availability, run state and alarms in one RSSO view
  • Every command is a request the site controller can refuse, with the reason shown
  • Nothing shows as applied until the controller acknowledges it
Source dispatch · 14:30 interval
Grid import1,718 kWAt target · unmanaged 2,318 kW
Battery storage · discharging544 kW SoC 58% · range 20–90%
The RSSOCoordinatingGrid, battery storage and chiller trim
Chiller staging trim56 kWRequested via RSLM · Chiller Optimization
Discharge 544 kWSending…Acknowledged by controllerApplied 14:30:12

Regens Smart Load Management

Consumption and verified savings. RSLM sets the IPMVP-ready baseline and tracks every measure against it, with two sub-modules for the loads that matter most.

  • RSLM · Chiller Optimization: plant efficiency in kW/RT, with setpoint and staging recommendations
  • RSLM · Lighting Optimization: schedules, occupancy dimming and circuit-level analytics
  • Savings tracked per measure, per site, against the agreed baseline
RSLM · Chiller Optimization
Plant efficiency0.68kW/RT+0.08 vs target
Target0.60kW/RTdesign basis
Verified this month42.6MWhvs 2025 baseline
Chiller plant is running 0.08 kW/RT above target. Staging change recommended: run 2 chillers at 78% load instead of 3 at 52%. est. 0.06 kW/RT lower
Lighting Optimization: 312 circuits scheduled, 18% dimmed by occupancy. 3.9 MWh saved this month

Regens Smart Billing Management

Tenant billing for malls and commercial buildings. RSBM bills from RSEM meter data, so every invoice traces back to a meter reading.

  • Automated monthly tenant invoices from sub-metered consumption
  • An audit trail from invoice line to meter ID and reading
  • Disputes logged against the reading they question
September billing · Mall B
Tenants billed186closed in 4 h
Meter coverage100%all reporting
Disputes0this cycle
Tenant unitMeterConsumption (kWh)Amount (RM)
L1-03SUB-11033,412.61,979.31
L2-14SUB-121412,086.27,010.00
L3-07SUB-1307842.0488.36

Supervisory by design.

Regens writes to live plant, so it is built to be refused. Protection, interlocks and synchronisation stay with your site controller. Every Regens command is a request the controller can decline, and the platform shows the reason.

  • Segmented OT and ITOT-native intrusion prevention at the plant edge and a next-generation firewall at the IT/OT boundary, in Purdue-aligned zones.
  • Confirmation in proportion to consequencePlant-wide changes need hold-to-confirm. Nothing shows as applied until the controller acknowledges it.
  • Every write loggedWho, when, the old value and the new value, in each site's activity log.
Reference architecturePurdue levels
L4–5
Enterprise and cloudRegens platform: forecasts, dashboards, verification reports
IT/OT boundary firewall
L3
Site operationsRegens edge gateway: interval data in, dispatch requests out
OT-native intrusion prevention
L2
Supervisory control · yoursSite controller: protection, interlocks, synchronisation
L1
Meters and controllersPower meters, chiller plant controls, storage PCS
L0
PlantChillers, lighting circuits, battery storage